IS 456: Plain and reinforced concrete

Limit state design of reinforced concrete beams, slabs, columns and footings, with material properties, cover and detailing.

Comparable Eurocode: EN 1992

Table

Concrete design properties

Characteristic and design properties of all concrete grades M15 to M80: design strength, modulus of elasticity, flexural strength, maximum shear stress, bond stress and limiting moment coefficients.

Clauses 6.1 & Table 2, 6.2.2, 6.2.3.1, 26.2.1.1
Calculator

Nominal cover

Determines the nominal cover to reinforcement from exposure condition (Table 16), fire resistance (Table 16A) and the member-specific minimums for columns and footings.

Clauses 8.2.2.1 & Table 3, Table 5, 26.4, Table 16
Calculator

Development & lap length

Design development length Ld of bars in tension and compression, including deformed bar and bundled bar factors, with lap lengths for flexural tension, direct tension and compression, plus a full table for all bar diameters.

Clauses 26.2.1, 26.2.1.1, 26.2.1.2, 26.2.3
Table

Rebar area tables

Cross-sectional area of 1 to 12 bars, mass per metre, and area per metre width for common spacings, for bar diameters 6 mm to 40 mm (IS 1786).

Clauses IS 1786, SP 16 Tables 95–96
Calculator

Rectangular beam — flexure

Limit state design of a rectangular reinforced concrete section for bending: limiting moment Mu,lim, required tension steel, compression steel for doubly reinforced sections using the design stress-strain curve, and moment capacity of the provided bars.

Clauses 26.5.1.1, 38.1, Annex G-1.1, Annex G-1.2
Calculator

T / L beam — flexure

Effective flange width and limit state flexural design of monolithic T- and L-beams: neutral axis in the flange or web, limiting moment of the flanged section and required tension reinforcement.

Clauses 23.1.2, 38.1, Annex G-2.1, Annex G-2.2
Calculator

Shear design

Nominal shear stress, design shear strength of concrete τc from Table 19, maximum shear stress τc,max, and design of vertical stirrups including minimum shear reinforcement and maximum spacing.

Clauses 26.5.1.5, 26.5.1.6, 40.1, 40.2
Calculator

Torsion design

Design of rectangular beams for combined torsion, shear and bending by the IS 456 equivalent shear and equivalent moment approach: longitudinal steel for Me1 (and Me2 on the compression face), closed stirrups for torsion plus shear, and the spacing rules for torsion links.

Clauses 26.5.1.7, 41.1, 41.3, 41.4.2
Calculator

Deflection (span/depth)

Checks deflection of beams and slabs through the basic span/effective depth ratios of cl. 23.2.1 with modification factors for tension steel (Fig. 4), compression steel (Fig. 5), flanged sections (Fig. 6) and spans over 10 m.

Clauses 23.2, 23.2.1, Fig. 4, Fig. 5
Calculator

Crack width (SLS)

Serviceability check of flexural crack width: elastic cracked section analysis (neutral axis, steel and concrete stresses), average strain with tension stiffening, and the design surface crack width at the soffit between bars and at the corner, compared with the limits of cl. 35.3.2.

Clauses 35.3.2, 43.1, Annex B-1.3, Annex F
Calculator

One-way / cantilever slab

Design of slabs spanning in one direction: loads, bending moments (with the Table 12 and 13 coefficients for continuous slabs), main and distribution reinforcement with spacing limits, shear and the span/depth deflection check.

Clauses 22.5, 24.4, 26.3.3(b), 26.5.2.1
Calculator

Two-way slab

Design of rectangular slabs spanning in two directions for any of the nine edge conditions of Table 26 or simply supported (Table 27): moments, reinforcement in both directions, spacing limits, shear and span/depth deflection check.

Clauses 24.4, 26.3.3, 26.5.2.1, 23.2.1
Calculator

Column — biaxial bending

Short and slender rectangular columns under axial load and biaxial moments: minimum eccentricity, additional moments for slender columns, P–M interaction diagrams by strain compatibility, Puz and the Bresler-type interaction check of cl. 39.6.

Clauses 25.1.2, 25.4, 26.5.3.1, 39.1
Calculator

Isolated footing

Design of a rectangular pad footing of uniform thickness for a concentric column load: plan size from safe bearing capacity, bending at the column face, one-way and two-way (punching) shear, development length, bearing at the column base and reinforcement distribution.

Clauses 31.6.3, 34.1, 34.2.3, 34.2.4