IS 456:2000

ULS flexural design of rectangular RC beam (singly / doubly reinforced)

Limit state design of a rectangular reinforced concrete section for bending: limiting moment Mu,lim, required tension steel, compression steel for doubly reinforced sections using the design stress-strain curve, and moment capacity of the provided bars.

References:cl. 26.5.1.1cl. 38.1Annex G-1.1Annex G-1.2Fig. 23
Design is adequateGoverning: (cl. G-1.1)
96%max. utilisation
Report details
Limiting moment Mu,limM_{u,lim}
250.5 kN·m
Required tension steel Ast,reqA_{st,req}
1418 mm²
Required compression steel Asc,reqA_{sc,req}
0 mm²
Moment capacity (provided) MuRM_{uR}
268.6 kN·m
Neutral axis depth xux_u
204.0 mm
Steel ratio ptp_t
0.98 %

Design checks 7

CheckClauseDemandLimitUtilisation
G-1.1250.0 kN·m268.6 kN·m93%OK
G-1.11472.6 mm²1418.2 mm²96%OK
26.5.1.1(b)1472.6 mm²6600.0 mm²22%OK
26.5.1.2226.2 mm²6600.0 mm²3%OK
26.3.2(a)75.0 mm25.0 mm33%OK
26.3.3(a), Table 1575.0 mm150.0 mm50%OK
26.3.2(a)188.0 mm25.0 mm13%OK
Cross-section
b = 300D = 550NA, xu = 2043–Ø252–Ø12
Bar arrangements for the required tension steel (single layer)
BarsArea (mm²)Clear spacing (mm)Single layer
13 – Ø1214705✕ too congested
8 – Ø16160813✕ too congested
5 – Ø20157130✓ fits
3 – Ø25147375✓ fits
3 – Ø28184772✓ fits
2 – Ø321608168✕ too far apart

Required area 1418 mm². Clear spacing limits: ≥ max(φ, 25 mm) and ≤ 150 mm (Table 15).

Detailed calculation

Geometry and materials

2
d=D−dc=550−50=500 mmd = D - d_c = 550 - 50 = 500\ \mathrm{mm}
xu,maxd=0.460(Fe 500)\dfrac{x_{u,max}}{d} = 0.460\quad (\text{Fe 500})
38.1 Note

Limiting moment of resistance

2
xu,max=0.460×500=230.0 mmx_{u,max} = 0.460 \times 500 = 230.0\ \mathrm{mm}
38.1
Mu,lim=0.36 xu,maxd(1−0.42 xu,maxd)fck b d2=0.1336×25×300×5002=250.5 kN mM_{u,lim} = 0.36\,\dfrac{x_{u,max}}{d}\left(1 - 0.42\,\dfrac{x_{u,max}}{d}\right) f_{ck}\,b\,d^2 = 0.1336 \times 25 \times 300 \times 500^2 = 250.5\ \mathrm{kN\,m}
G-1.1(c)

Singly reinforced design (Mu ≤ Mu,lim)

2
Ast=0.5 fckfy[1−1−4.6 Mufck b d2]b d=1418 mm2A_{st} = \dfrac{0.5\,f_{ck}}{f_y}\left[1 - \sqrt{1 - \dfrac{4.6\,M_u}{f_{ck}\,b\,d^2}}\right] b\,d = 1418\ \mathrm{mm^{2}}
G-1.1(b)
xu=0.87 fy Ast0.36 fck b=228.5 mm≤xu,max=230.0 mmx_u = \dfrac{0.87\,f_y\,A_{st}}{0.36\,f_{ck}\,b} = 228.5\ \mathrm{mm} \le x_{u,max} = 230.0\ \mathrm{mm}
G-1.1(a)

Reinforcement limits

2
Ast,min=0.85 b dfy=255 mm2A_{st,min} = \dfrac{0.85\,b\,d}{f_y} = 255\ \mathrm{mm^{2}}
26.5.1.1(a)
As,max=0.04 b D=6600 mm2A_{s,max} = 0.04\,b\,D = 6600\ \mathrm{mm^{2}}
26.5.1.1(b), 26.5.1.2

Moment capacity of provided reinforcement

4
Ast,prov=1473 mm2,Asc,prov=226 mm2A_{st,prov} = 1473\ \mathrm{mm^{2}},\quad A_{sc,prov} = 226\ \mathrm{mm^{2}}
0.36 fck b xu+fscAsc=fstAst⇒xu=204.0 mm0.36\,f_{ck}\,b\,x_u + f_{sc}A_{sc} = f_{st}A_{st} \Rightarrow x_u = 204.0\ \mathrm{mm}
38.1
fst=435.0 MPa (εst=0.00508),fsc,net=396.8 MPaf_{st} = 435.0\ \mathrm{MPa}\ (\varepsilon_{st} = 0.00508),\quad f_{sc,net} = 396.8\ \mathrm{MPa}
Fig. 23
MuR=0.36 fck b xu (d−0.42 xu)+fscAsc(d−d′)=268.6 kN mM_{uR} = 0.36\,f_{ck}\,b\,x_u\,(d - 0.42\,x_u) + f_{sc}A_{sc}(d - d') = 268.6\ \mathrm{kN\,m}
G-1.1

Bar spacing (detailing)

3

Bar centres are taken at the effective cover from the side faces; 20 mm maximum aggregate size is assumed.

sclear=b−2×50n−1−ϕ=300−1002−25=75 mms_{clear} = \dfrac{b - 2 \times 50}{n - 1} - \phi = \dfrac{300 - 100}{2} - 25 = 75\ \mathrm{mm}
26.3.2
sclear=b−2×50n−1−ϕ=300−1001−12=188 mms_{clear} = \dfrac{b - 2 \times 50}{n - 1} - \phi = \dfrac{300 - 100}{1} - 12 = 188\ \mathrm{mm}
26.3.2
✓ OK · 96%InputsResults

Scope, assumptions and limitations

  • Rectangular stress block of IS 456 cl. 38.1 (0.36 fck xu, centroid 0.42 xu). Tension steel assumed to yield (xu ≤ xu,max).
  • For doubly reinforced sections the compression steel stress fsc is taken from the design stress-strain curve (Fig. 23) at εsc = 0.0035 (xu,max − d′)/xu,max, with the displaced concrete (0.446 fck) deducted.
  • Moment capacity of provided bars accounts for compression bars by strain compatibility.