ULS flexural design of rectangular RC beam (singly / doubly reinforced)
Limit state design of a rectangular reinforced concrete section for bending: limiting moment Mu,lim, required tension steel, compression steel for doubly reinforced sections using the design stress-strain curve, and moment capacity of the provided bars.
References:cl. 26.5.1.1cl. 38.1Annex G-1.1Annex G-1.2Fig. 23
IndianCodeApplied — calculation report
| Calculation | ULS flexural design of rectangular RC beam (singly / doubly reinforced) |
|---|---|
| Project | — |
| Engineer | — |
| Reference | — |
| Date |
Inputs
| Width | 300 mm |
|---|---|
| Overall depth | 550 mm |
| Effective cover to tension steel | 50 mm |
| Effective cover to compression steel | 50 mm |
| Concrete grade | M25 |
| Steel grade | Fe 500 (HYSD) |
| Factored bending moment | 250 kN m |
| Tension bars — number | 3 |
| Tension bars — diameter | 25 mm |
| Compression bars — number | 2 |
| Compression bars — diameter | 12 mm |
Design is adequateGoverning: (cl. G-1.1)
96%max. utilisation
Limiting moment
250.5 kN·m
Required tension steel
1418 mm²
Required compression steel
0 mm²
Moment capacity (provided)
268.6 kN·m
Neutral axis depth
204.0 mm
Steel ratio
0.98 %
Design checks 7
| Check | Clause | Demand | Limit | Utilisation |
|---|---|---|---|---|
| G-1.1 | 250.0 kN·m | 268.6 kN·m | 93%OK | |
| G-1.1 | 1472.6 mm² | 1418.2 mm² | 96%OK | |
| 26.5.1.1(b) | 1472.6 mm² | 6600.0 mm² | 22%OK | |
| 26.5.1.2 | 226.2 mm² | 6600.0 mm² | 3%OK | |
| 26.3.2(a) | 75.0 mm | 25.0 mm | 33%OK | |
| 26.3.3(a), Table 15 | 75.0 mm | 150.0 mm | 50%OK | |
| 26.3.2(a) | 188.0 mm | 25.0 mm | 13%OK |
| Bars | Area (mm²) | Clear spacing (mm) | Single layer |
|---|---|---|---|
| 13 – Ø12 | 1470 | 5 | ✕ too congested |
| 8 – Ø16 | 1608 | 13 | ✕ too congested |
| 5 – Ø20 | 1571 | 30 | ✓ fits |
| 3 – Ø25 | 1473 | 75 | ✓ fits |
| 3 – Ø28 | 1847 | 72 | ✓ fits |
| 2 – Ø32 | 1608 | 168 | ✕ too far apart |
Required area 1418 mm². Clear spacing limits: ≥ max(φ, 25 mm) and ≤ 150 mm (Table 15).
Detailed calculation
Geometry and materials
2
38.1 Note
Limiting moment of resistance
2
38.1
G-1.1(c)
Singly reinforced design (Mu ≤ Mu,lim)
2
G-1.1(b)
G-1.1(a)
Reinforcement limits
2
26.5.1.1(a)
26.5.1.1(b), 26.5.1.2
Moment capacity of provided reinforcement
4
38.1
Fig. 23
G-1.1
Bar spacing (detailing)
3
Bar centres are taken at the effective cover from the side faces; 20 mm maximum aggregate size is assumed.
26.3.2
26.3.2
Scope, assumptions and limitations
- Rectangular stress block of IS 456 cl. 38.1 (0.36 fck xu, centroid 0.42 xu). Tension steel assumed to yield (xu ≤ xu,max).
- For doubly reinforced sections the compression steel stress fsc is taken from the design stress-strain curve (Fig. 23) at εsc = 0.0035 (xu,max − d′)/xu,max, with the displaced concrete (0.446 fck) deducted.
- Moment capacity of provided bars accounts for compression bars by strain compatibility.