Calculation One-way slab design — simply supported, continuous or cantilever Project — Engineer — Reference — Date
Inputs Support condition Continuous over 3+ spans (Table 12 / 13) Effective span 3.5 m Slab thickness 150 mm Clear cover 20 mm Main bar diameter 10 mm Distribution bar diameter 8 mm Concrete grade M25 Steel grade Fe 500 (HYSD) Floor finish + other dead load 1.5 kN/m² Imposed load 3 kN/m² Load factor 1.5
✓
Design is adequate Governing: Span/depth ratio (cl. 23.2.1)
Main steel (span)
Ø10 @ 300 mm
Distribution steel
Ø8 @ 270 mm
Main reinforcement schedule (per metre width) Copy CSV
Detailed calculation Collapse all Loads per metre width 2 g k = 25 × 0.150 + 1.50 = 5.25 k N / m 2 , q k = 3.00 k N / m 2 g_k = 25 \times 0.150 + 1.50 = 5.25\ \mathrm{kN/m^{2}},\quad q_k = 3.00\ \mathrm{kN/m^{2}} g k = 25 × 0.150 + 1.50 = 5.25 kN/ m 2 , q k = 3.00 kN/ m 2 IS 875-1, 2 d = D − c − ϕ / 2 = 150 − 20 − 5 = 125.0 m m d = D - c - \phi/2 = 150 - 20 - 5 = 125.0\ \mathrm{mm} d = D − c − ϕ /2 = 150 − 20 − 5 = 125.0 mm Design moments and shears 5 Middle of end span (bottom) : M u = 1.50 ( 0.0833 × 5.25 + 0.1000 × 3.00 ) 3.50 2 = 13.55 k N m / m \text{Middle of end span (bottom)}:\ M_u = 1.50\left(0.0833 \times 5.25 + 0.1000 \times 3.00\right) 3.50^2 = 13.55\ \mathrm{kN\,m/m} Middle of end span (bottom) : M u = 1.50 ( 0.0833 × 5.25 + 0.1000 × 3.00 ) 3.5 0 2 = 13.55 kN m/m Table 12 Support next to end support (top) : M u = 1.50 ( − 0.1000 × 5.25 + − 0.1111 × 3.00 ) 3.50 2 = 15.77 k N m / m \text{Support next to end support (top)}:\ M_u = 1.50\left(-0.1000 \times 5.25 + -0.1111 \times 3.00\right) 3.50^2 = 15.77\ \mathrm{kN\,m/m} Support next to end support (top) : M u = 1.50 ( − 0.1000 × 5.25 + − 0.1111 × 3.00 ) 3.5 0 2 = 15.77 kN m/m Table 12 Middle of interior span (bottom) : M u = 1.50 ( 0.0625 × 5.25 + 0.0833 × 3.00 ) 3.50 2 = 10.62 k N m / m \text{Middle of interior span (bottom)}:\ M_u = 1.50\left(0.0625 \times 5.25 + 0.0833 \times 3.00\right) 3.50^2 = 10.62\ \mathrm{kN\,m/m} Middle of interior span (bottom) : M u = 1.50 ( 0.0625 × 5.25 + 0.0833 × 3.00 ) 3.5 0 2 = 10.62 kN m/m Table 12 Other interior supports (top) : M u = 1.50 ( − 0.0833 × 5.25 + − 0.1111 × 3.00 ) 3.50 2 = 14.16 k N m / m \text{Other interior supports (top)}:\ M_u = 1.50\left(-0.0833 \times 5.25 + -0.1111 \times 3.00\right) 3.50^2 = 14.16\ \mathrm{kN\,m/m} Other interior supports (top) : M u = 1.50 ( − 0.0833 × 5.25 + − 0.1111 × 3.00 ) 3.5 0 2 = 14.16 kN m/m Table 12 V u = 1.50 ( 0.6 × 5.25 + 0.6 × 3.00 ) × 3.50 = 25.99 k N / m ( support next to end, outer side ) V_u = 1.50(0.6 \times 5.25 + 0.6 \times 3.00) \times 3.50 = 25.99\ \mathrm{kN/m}\ (\text{support next to end, outer side}) V u = 1.50 ( 0.6 × 5.25 + 0.6 × 3.00 ) × 3.50 = 25.99 kN/m ( support next to end, outer side ) Table 13 Main reinforcement 5 A s , m i n = 0.12 % × 1000 × 150 = 180 m m 2 / m , s m a x = min ( 3 d , 300 ) = 300 m m A_{s,min} = 0.12\% \times 1000 \times 150 = 180\ \mathrm{mm^{2}/m},\quad s_{max} = \min(3d,\ 300) = 300\ \mathrm{mm} A s , min = 0.12% × 1000 × 150 = 180 m m 2 /m , s ma x = min ( 3 d , 300 ) = 300 mm 26.5.2.1, 26.3.3(b) Middle of end span (bottom) : A s t = 260 → 260 m m 2 / m ⇒ ϕ 10 @ 300 \text{Middle of end span (bottom)}:\ A_{st} = 260 \to 260\ \mathrm{mm^{2}/m} \Rightarrow \phi10\ @\ 300 Middle of end span (bottom) : A s t = 260 → 260 m m 2 /m ⇒ ϕ 10 @ 300 G-1.1(b) Support next to end support (top) : A s t = 305 → 305 m m 2 / m ⇒ ϕ 10 @ 250 \text{Support next to end support (top)}:\ A_{st} = 305 \to 305\ \mathrm{mm^{2}/m} \Rightarrow \phi10\ @\ 250 Support next to end support (top) : A s t = 305 → 305 m m 2 /m ⇒ ϕ 10 @ 250 G-1.1(b) Middle of interior span (bottom) : A s t = 202 → 202 m m 2 / m ⇒ ϕ 10 @ 300 \text{Middle of interior span (bottom)}:\ A_{st} = 202 \to 202\ \mathrm{mm^{2}/m} \Rightarrow \phi10\ @\ 300 Middle of interior span (bottom) : A s t = 202 → 202 m m 2 /m ⇒ ϕ 10 @ 300 G-1.1(b) Other interior supports (top) : A s t = 272 → 272 m m 2 / m ⇒ ϕ 10 @ 280 \text{Other interior supports (top)}:\ A_{st} = 272 \to 272\ \mathrm{mm^{2}/m} \Rightarrow \phi10\ @\ 280 Other interior supports (top) : A s t = 272 → 272 m m 2 /m ⇒ ϕ 10 @ 280 G-1.1(b) Distribution reinforcement 1 A s , d i s t = A s , m i n = 180 m m 2 / m , s ≤ min ( 5 d , 450 ) = 450 ⇒ ϕ 8 @ 270 A_{s,dist} = A_{s,min} = 180\ \mathrm{mm^{2}/m},\quad s \le \min(5d,\ 450) = 450 \Rightarrow \phi8\ @\ 270 A s , d i s t = A s , min = 180 m m 2 /m , s ≤ min ( 5 d , 450 ) = 450 ⇒ ϕ 8 @ 270 26.5.2.1, 26.3.3(b)(2) Shear 1 τ v = V u b d = 0.208 M P a , k τ c = 1.30 × 0.338 = 0.439 M P a \tau_v = \dfrac{V_u}{b\,d} = 0.208\ \mathrm{MPa},\quad k\,\tau_c = 1.30 \times 0.338 = 0.439\ \mathrm{MPa} τ v = b d V u = 0.208 MPa , k τ c = 1.30 × 0.338 = 0.439 MPa 40.2.1.1 Deflection — span/depth ratio 2 f s = 288.2 M P a , p t = 0.209 % ⇒ k t = 1.372 ; ( l d ) a l l o w = 26 × 1.372 = 35.7 f_s = 288.2\ \mathrm{MPa},\ p_t = 0.209\% \Rightarrow k_t = 1.372;\quad \left(\dfrac{l}{d}\right)_{allow} = 26 \times 1.372 = 35.7 f s = 288.2 MPa , p t = 0.209% ⇒ k t = 1.372 ; ( d l ) a l l o w = 26 × 1.372 = 35.7 23.2.1, Fig. 4 l d = 3500 125.0 = 28.0 \dfrac{l}{d} = \dfrac{3500}{125.0} = 28.0 d l = 125.0 3500 = 28.0 Scope, assumptions and limitations Table 12 / 13 coefficients apply to continuous slabs of three or more spans that do not differ by more than 15% of the longest, under substantially uniform load (cl. 22.5.1). Cantilever moments are taken at the support face (wl²/2); main steel is then at the top. Check the back-span for anchorage and balancing moment separately.