IS 456:2000

Deflection control by span / effective depth ratio

Checks deflection of beams and slabs through the basic span/effective depth ratios of cl. 23.2.1 with modification factors for tension steel (Fig. 4), compression steel (Fig. 5), flanged sections (Fig. 6) and spans over 10 m.

References:cl. 23.2cl. 23.2.1Fig. 4Fig. 5Fig. 6
Design is adequateGoverning: (cl. 23.2.1)
54%max. utilisation
Report details
Allowable span/depth (l/d)allow(l/d)_{allow}
20.67
Actual span/depth l/dl/d
11.11
Tension factor ktk_t
0.990
Compression factor kck_c
1.044
Minimum effective depth dmind_{min}
290 mm

Design checks 1

CheckClauseDemandLimitUtilisation
23.2.111.1 20.7 54%OK
Fig. 4 — modification factor kt
12014016018020022024026028000.511.52designfs (MPa)kt
  • pt = 0.25%
  • pt = 0.5%
  • pt = 1%
  • pt = 2%
  • pt = 3%

Detailed calculation

Basic ratio

1
(ld)basic=20\left(\dfrac{l}{d}\right)_{basic} = 20
23.2.1(a)

Modification factors

3
fs=0.58 fy Ast,reqAst,prov=0.58×500×11501257=265.3 MPaf_s = 0.58\,f_y\,\dfrac{A_{st,req}}{A_{st,prov}} = 0.58 \times 500 \times \dfrac{1150}{1257} = 265.3\ \mathrm{MPa}
Fig. 4
pt=100 Astb d=0.776 %⇒kt=0.990p_t = \dfrac{100\,A_{st}}{b\,d} = 0.776\,\% \Rightarrow k_t = 0.990
Fig. 4
pc=0.140 %⇒kc=1.044p_c = 0.140\,\% \Rightarrow k_c = 1.044
Fig. 5

Verification

2
(ld)allow=20.00×0.990×1.044=20.67\left(\dfrac{l}{d}\right)_{allow} = 20.00 \times 0.990 \times 1.044 = 20.67
23.2.1
ld=6000540=11.11\dfrac{l}{d} = \dfrac{6000}{540} = 11.11
✓ OK · 54%InputsResults

Scope, assumptions and limitations

  • kt uses the widely adopted closed-form fit of Fig. 4: kt = 1 / [0.225 + 0.00322 fs − 0.625 log10(1/pt)] ≤ 2.0. kc = 1 + pc/(3 + pc) ≤ 1.5 (Fig. 5).
  • For flanged beams pt and pc are based on bf·d (Fig. 4, 5 notes); basic values are reduced per Fig. 6.
  • Cantilevers longer than 10 m require deflection calculations (cl. 23.2.1(b)).