Deflection control by span / effective depth ratio
Checks deflection of beams and slabs through the basic span/effective depth ratios of cl. 23.2.1 with modification factors for tension steel (Fig. 4), compression steel (Fig. 5), flanged sections (Fig. 6) and spans over 10 m.
References:cl. 23.2cl. 23.2.1Fig. 4Fig. 5Fig. 6
IndianCodeApplied — calculation report
| Calculation | Deflection control by span / effective depth ratio |
|---|---|
| Project | — |
| Engineer | — |
| Reference | — |
| Date |
Inputs
| Support condition | Simply supported (basic 20) |
|---|---|
| Effective span | 6 m |
| Width (web width for flanged) | 300 mm |
| Effective depth | 540 mm |
| Flanged section | No |
| Steel grade | Fe 500 (HYSD) |
| Tension steel required | 1150 mm² |
| Tension steel provided | 1257 mm² |
| Compression steel provided | 226 mm² |
Design is adequateGoverning: (cl. 23.2.1)
54%max. utilisation
Allowable span/depth
20.67
Actual span/depth
11.11
Tension factor
0.990
Compression factor
1.044
Minimum effective depth
290 mm
Design checks 1
| Check | Clause | Demand | Limit | Utilisation |
|---|---|---|---|---|
| 23.2.1 | 11.1 | 20.7 | 54%OK |
- pt = 0.25%
- pt = 0.5%
- pt = 1%
- pt = 2%
- pt = 3%
Detailed calculation
Basic ratio
1
23.2.1(a)
Modification factors
3
Fig. 4
Fig. 4
Fig. 5
Verification
2
23.2.1
Scope, assumptions and limitations
- kt uses the widely adopted closed-form fit of Fig. 4: kt = 1 / [0.225 + 0.00322 fs − 0.625 log10(1/pt)] ≤ 2.0. kc = 1 + pc/(3 + pc) ≤ 1.5 (Fig. 5).
- For flanged beams pt and pc are based on bf·d (Fig. 4, 5 notes); basic values are reduced per Fig. 6.
- Cantilevers longer than 10 m require deflection calculations (cl. 23.2.1(b)).