Two-way slab design using IS 456 moment coefficients (Tables 26 & 27)
Design of rectangular slabs spanning in two directions for any of the nine edge conditions of Table 26 or simply supported (Table 27): moments, reinforcement in both directions, spacing limits, shear and span/depth deflection check.
References:cl. 24.4cl. 26.3.3cl. 26.5.2.1cl. 23.2.1cl. 40.2.1.1Annex DTable 26Table 27
IndianCodeApplied — calculation report
| Calculation | Two-way slab design using IS 456 moment coefficients (Tables 26 & 27) |
|---|---|
| Project | — |
| Engineer | — |
| Reference | — |
| Date |
Inputs
| Short span | 4 m |
|---|---|
| Long span | 5 m |
| Edge condition | 1. Interior panel |
| Slab thickness | 150 mm |
| Clear cover | 20 mm |
| Bar diameter | 10 mm |
| Concrete grade | M25 |
| Steel grade | Fe 500 (HYSD) |
| Floor finish + other dead load | 1.5 kN/m² |
| Imposed load | 3 kN/m² |
| Load factor | 1.5 |
Design is adequateGoverning: (cl. 23.2.1)
62%max. utilisation
Factored load
12.38 kN/m²
Short span midspan moment
6.73 kN·m/m
Long span midspan moment
4.75 kN·m/m
Short span bottom steel
Ø10 @ 300 mm
Effective depth (short)
125 mm
Design checks 3
| Check | Clause | Demand | Limit | Utilisation |
|---|---|---|---|---|
| G-1.1 | 51.6 mm | 125.0 mm | 41%OK | |
| 40.2.1.1 | 0.198 MPa | 0.439 MPa | 45%OK | |
| 23.2.1 | 32.0 | 52.0 | 62%OK |
| Location | Mu (kN·m/m) | d (mm) | Ast,req (mm²/m) | Ast,design (mm²/m) | Provide | Ast,prov (mm²/m) |
|---|---|---|---|---|---|---|
| Mx^+ | 6.73 | 125 | 126 | 180 | Ø10 @ 300 | 262 |
| Mx^- | 8.91 | 125 | 168 | 180 | Ø10 @ 300 | 262 |
| My^+ | 4.75 | 115 | 97 | 180 | Ø10 @ 300 | 262 |
| My^- | 6.34 | 115 | 130 | 180 | Ø10 @ 300 | 262 |
Detailed calculation
Loads
2
IS 875-1
Table 18
Moment coefficients
3
1. Interior panel
Table 26
Design moments per metre width
2
D-1.1
Depth check
1
G-1.1(c)
Reinforcement
5
26.5.2.1
26.3.3(b)
26.3.3(b)
26.3.3(b)
26.3.3(b)
Shear check
2
40.1
40.2.1.1
Deflection — span/depth ratio (short span)
3
Fig. 4
23.2.1
24.1
Scope, assumptions and limitations
- Bars in the long direction are placed above the short-span bars, so dy = dx − φ.
- Table 26 is valid for ly/lx ≤ 2; beyond that the slab is designed as one-way.
- Corner torsion reinforcement (Annex D-1.8) is reported but not detailed.