Crack width of a rectangular RC section under service moment (Annex F)
Serviceability check of flexural crack width: elastic cracked section analysis (neutral axis, steel and concrete stresses), average strain with tension stiffening, and the design surface crack width at the soffit between bars and at the corner, compared with the limits of cl. 35.3.2.
References:cl. 35.3.2cl. 43.1Annex B-1.3Annex FTable 21
IndianCodeApplied — calculation report
| Calculation | Crack width of a rectangular RC section under service moment (Annex F) |
|---|---|
| Project | — |
| Engineer | — |
| Reference | — |
| Date |
Inputs
| Width | 300 mm |
|---|---|
| Overall depth | 600 mm |
| Clear cover to tension bars | 40 mm |
| Side cover to bar centre | 50 mm |
| Number of tension bars | 4 |
| Bar diameter | 20 mm |
| Concrete grade | M25 |
| Steel grade | Fe 500 (HYSD) |
| Modular ratio | m = 280 / 3σcbc (long-term, Annex B) |
| Service bending moment | 110 kN m |
| Permissible crack width | 0.3 mm — general |
Design is adequateGoverning: (cl. Table 21)
96%max. utilisation
Design crack width
0.137 mm
Steel stress (service)
179.1 MPa
Neutral axis depth
183.6 mm
Average strain
829 ×10⁻⁶
Design checks 2
| Check | Clause | Demand | Limit | Utilisation |
|---|---|---|---|---|
| 35.3.2 | 0.137 mm | 0.300 mm | 46%OK | |
| Table 21 | 8.172 MPa | 8.500 MPa | 96%OK |
- wcr
- limit
Detailed calculation
Elastic cracked section
4
B-1.3(d), Table 21
B-2
B-2
Average strain at the tension face
2
Annex F
Annex F
Design surface crack width
3
Annex F
Annex F
Annex F
Scope, assumptions and limitations
- Single layer of tension bars, compression steel neglected. Crack width is assessed at the tension face midway between bars and at the bottom corner; the larger value governs.
- Annex F gives a surface crack width with an acceptable probability of not being exceeded; it is not an exact prediction.