Isolated rectangular pad footing under axial load
Design of a rectangular pad footing of uniform thickness for a concentric column load: plan size from safe bearing capacity, bending at the column face, one-way and two-way (punching) shear, development length, bearing at the column base and reinforcement distribution.
References:cl. 31.6.3cl. 34.1cl. 34.2.3cl. 34.2.4cl. 34.3cl. 34.4cl. 26.2.1cl. 26.5.2.1
IndianCodeApplied — calculation report
| Calculation | Isolated rectangular pad footing under axial load |
|---|---|
| Project | — |
| Engineer | — |
| Reference | — |
| Date |
Inputs
| Column dimension along L | 400 mm |
|---|---|
| Column dimension along B | 400 mm |
| Service axial load | 1200 kN |
| Load factor | 1.5 |
| Self-weight + backfill allowance | 10 % |
| Net safe bearing capacity | 200 kN/m² |
| Footing length | 2600 mm |
| Footing width | 2600 mm |
| Footing depth | 600 mm |
| Clear cover | 50 mm |
| Bar diameter | 16 mm |
| Concrete grade | M25 |
| Steel grade | Fe 500 (HYSD) |
Design is adequateGoverning: (cl. 34.1)
98%max. utilisation
Factored soil pressure
266.3 kN/m²
Bars along L
10 – Ø16 @ 275
Bars along B
10 – Ø16 @ 275
Moment at face (L)
418.8 kN·m
Punching shear stress
0.786 MPa
Design checks 8
| Check | Clause | Demand | Limit | Utilisation |
|---|---|---|---|---|
| 34.1 | 6.760 m² | 6.600 m² | 98%OK | |
| 26.3.2(a) | 260.0 mm | 25.0 mm | 10%OK | |
| 26.3.2(a) | 260.0 mm | 25.0 mm | 10%OK | |
| 34.2.4.1(a) | 0.282 MPa | 0.291 MPa | 97%OK | |
| 34.2.4.1(a) | 0.282 MPa | 0.291 MPa | 97%OK | |
| 31.6.3 | 0.786 MPa | 1.250 MPa | 63%OK | |
| 26.2.1 | 1050.0 mm | 776.8 mm | 74%OK | |
| 34.4 | 11.3 MPa | 22.5 MPa | 50%OK |
Detailed calculation
Plan area
2
34.1
Factored net soil pressure
1
Bending at column face
7
34.2.3.1
34.2.3.1
G-1.1, 34.5.2
G-1.1, 34.5.2
One-way shear at d from column face
3
34.2.4.1(a)
Table 19
34.2.4.1(a)
Two-way (punching) shear at d/2 from column face
3
31.6.1
34.2.4.1(b)
31.6.3.1
Development length
1
34.2.4.3
Bearing at column base
2
34.4
34.4
Scope, assumptions and limitations
- Uniform soil pressure under a concentric axial load; footing self weight does not produce bending or shear and is excluded from the factored net pressure.
- The effective depth for the L-direction bars is d = D − cover − φ/2 (bottom layer); for the B-direction d − φ. Shear checks use the average depth.
- Bearing at the column base uses A1 from a 1V:2H frustum within the footing (cl. 34.4).