IS 456:2000

Shear design of RC beams and slabs (stirrups)

Nominal shear stress, design shear strength of concrete τc from Table 19, maximum shear stress τc,max, and design of vertical stirrups including minimum shear reinforcement and maximum spacing.

References:cl. 26.5.1.5cl. 26.5.1.6cl. 40.1cl. 40.2cl. 40.4Table 19Table 20
Design is adequateGoverning: (cl. 40.4)
94%max. utilisation
Report details
Nominal shear stress τv\tau_v
1.467 MPa
Shear strength of concrete τc\tau_c
0.600 MPa
Maximum shear stress τc,max\tau_{c,max}
3.10 MPa
Required stirrup spacing svs_v
135 mm
Shear capacity (provided) VuRV_{uR}
235.2 kN

Design checks 4

CheckClauseDemandLimitUtilisation
40.2.31.467 MPa3.100 MPa47%OK
40.4220.0 kN235.2 kN94%OK
40.4 / 26.5.1.6125.0 mm139.6 mm90%OK
26.5.1.5125.0 mm300.0 mm42%OK

Detailed calculation

Nominal shear stress

2
d=550−50=500 mmd = 550 - 50 = 500\ \mathrm{mm}
τv=Vub d=220.0×103300×500=1.467 MPa\tau_v = \dfrac{V_u}{b\,d} = \dfrac{220.0 \times 10^3}{300 \times 500} = 1.467\ \mathrm{MPa}
40.1

Design shear strength of concrete

4
pt=100 Asb d=0.838 %p_t = \dfrac{100\,A_s}{b\,d} = 0.838\,\%
Table 19
β=0.8 fck6.89 pt=3.464≥1\beta = \dfrac{0.8\,f_{ck}}{6.89\,p_t} = 3.464 \ge 1
SP 16
τc=0.850.8 fck(1+5β−1)6β=0.600 MPa\tau_c = \dfrac{0.85\sqrt{0.8\,f_{ck}}\left(\sqrt{1 + 5\beta} - 1\right)}{6\beta} = 0.600\ \mathrm{MPa}
Table 19
τc,max=3.10 MPa\tau_{c,max} = 3.10\ \mathrm{MPa}
Table 20

Shear reinforcement (vertical stirrups)

7
Asv=2×π4×82=100.5 mm2A_{sv} = 2 \times \dfrac{\pi}{4} \times 8^2 = 100.5\ \mathrm{mm^{2}}
Vc=τc b d=90.0 kNV_c = \tau_c\,b\,d = 90.0\ \mathrm{kN}
40.4
Vus=Vu−Vc=220.0−90.0=130.0 kNV_{us} = V_u - V_c = 220.0 - 90.0 = 130.0\ \mathrm{kN}
40.4
sv=0.87 fy Asv dVus=0.87×415×100.5×500130009=140 mms_v = \dfrac{0.87\,f_y\,A_{sv}\,d}{V_{us}} = \dfrac{0.87 \times 415 \times 100.5 \times 500}{130009} = 140\ \mathrm{mm}
40.4(a)
sv,min steel=0.87 fy Asv0.4 b=302 mm(fy≤415)s_{v,min\,steel} = \dfrac{0.87\,f_y\,A_{sv}}{0.4\,b} = 302\ \mathrm{mm}\quad (f_y \le 415)
26.5.1.6
sv,max=min⁡(0.75d, 300)=300 mms_{v,max} = \min(0.75d,\ 300) = 300\ \mathrm{mm}
26.5.1.5
sv,req=140 mms_{v,req} = 140\ \mathrm{mm}

Capacity with provided stirrups

2
Vus,prov=0.87×415×100.5×500125=145.2 kNV_{us,prov} = \dfrac{0.87 \times 415 \times 100.5 \times 500}{125} = 145.2\ \mathrm{kN}
40.4(a)
VuR=min⁡(Vc+Vus, τc,max b d)=235.2 kNV_{uR} = \min(V_c + V_{us},\ \tau_{c,max}\,b\,d) = 235.2\ \mathrm{kN}
✓ OK · 94%InputsResults

Scope, assumptions and limitations

  • τc is computed with the closed-form expression that generates Table 19: τc = 0.85√(0.8fck)(√(1+5β) − 1)/(6β), β = 0.8fck/(6.89pt) ≥ 1, with 0.15 ≤ pt ≤ 3 and fck ≤ 40 MPa.