IS 456:2000

ULS flexural design of T-beam and L-beam (flanged sections)

Effective flange width and limit state flexural design of monolithic T- and L-beams: neutral axis in the flange or web, limiting moment of the flanged section and required tension reinforcement.

References:cl. 23.1.2cl. 38.1Annex G-2.1Annex G-2.2
Design is adequateGoverning: (cl. G-2)
90%max. utilisation
Report details
Effective flange width bfb_f
2000 mm
Limiting moment Mu,limM_{u,lim}
1355.5 kN·m
Required tension steel Ast,reqA_{st,req}
1761 mm²
Neutral axis depth xux_u
42.6 mm
Moment capacity (provided) MuRM_{uR}
444.2 kN·m

Design checks 5

CheckClauseDemandLimitUtilisation
G-2400.0 kN·m444.2 kN·m90%OK
G-21963.5 mm²1761.1 mm²90%OK
26.5.1.1(b)1963.5 mm²7200.0 mm²27%OK
26.3.2(a)35.0 mm25.0 mm71%OK
26.3.3(a), Table 1535.0 mm150.0 mm23%OK
Effective cross-section
NA, xu = 43bf = 2000bw = 300D = 600
Bar arrangements in the web for the required steel (single layer)
BarsArea (mm²)Clear spacing (mm)Single layer
16 – Ø1218100✕ too congested
9 – Ø1618107✕ too congested
6 – Ø20188516✕ too congested
4 – Ø25196335✓ fits
3 – Ø28184762✓ fits
3 – Ø32241358✓ fits

Required area 1761 mm². Clear spacing limits: ≥ max(φ, 25 mm) and ≤ 150 mm (Table 15).

Detailed calculation

Effective flange width

2
bf=l06+bw+6Df=60006+300+6×120=2020 mmb_f = \dfrac{l_0}{6} + b_w + 6D_f = \dfrac{6000}{6} + 300 + 6 \times 120 = 2020\ \mathrm{mm}
23.1.2
bf=min⁡(2020, 2000)=2000 mmb_f = \min(2020,\ 2000) = 2000\ \mathrm{mm}
23.1.2

Limiting moment of the flanged section

3
d=600−60=540 mm,xu,max=0.460 d=248.4 mmd = 600 - 60 = 540\ \mathrm{mm},\quad x_{u,max} = 0.460\,d = 248.4\ \mathrm{mm}
38.1
Df/d=0.222>0.2⇒yf=115.3 mmD_f/d = 0.222 > 0.2 \Rightarrow y_f = 115.3\ \mathrm{mm}
G-2.2.1
Mu,lim=0.36xu,maxd(1−0.42xu,maxd)fckbwd2+0.45fck(bf−bw)yf(d−yf2)=1355.5 kN mM_{u,lim} = 0.36\tfrac{x_{u,max}}{d}\left(1 - 0.42\tfrac{x_{u,max}}{d}\right) f_{ck} b_w d^2 + 0.45 f_{ck}(b_f - b_w) y_f\left(d - \tfrac{y_f}{2}\right) = 1355.5\ \mathrm{kN\,m}
G-2.2.1

Required tension reinforcement

5
Mu,Df=0.36fckbfDf(d−0.42Df)=1057.5 kN mM_{u,D_f} = 0.36 f_{ck} b_f D_f (d - 0.42D_f) = 1057.5\ \mathrm{kN\,m}
G-2.1

Mu ≤ Mu,Df: neutral axis lies within the flange — design as rectangular section of width bf.

G-2.1
Ast=0.5fckfy[1−1−4.6Mufckbfd2]bfd=1761 mm2A_{st} = \dfrac{0.5 f_{ck}}{f_y}\left[1 - \sqrt{1 - \dfrac{4.6 M_u}{f_{ck} b_f d^2}}\right] b_f d = 1761\ \mathrm{mm^{2}}
G-1.1(b)
xu=42.6 mm≤Df=120 mmx_u = 42.6\ \mathrm{mm} \le D_f = 120\ \mathrm{mm}
Ast,min=0.85 bw dfy=275 mm2A_{st,min} = \dfrac{0.85\,b_w\,d}{f_y} = 275\ \mathrm{mm^{2}}
26.5.1.1(a)

Moment capacity of provided reinforcement

2
Ast,prov=1963 mm2⇒xu=47.5 mmA_{st,prov} = 1963\ \mathrm{mm^{2}}\Rightarrow x_u = 47.5\ \mathrm{mm}
38.1
MuR=444.2 kN mM_{uR} = 444.2\ \mathrm{kN\,m}
G-2

Bar spacing in the web (detailing)

1
sclear=b−2×60n−1−ϕ=300−1203−25=35 mms_{clear} = \dfrac{b - 2 \times 60}{n - 1} - \phi = \dfrac{300 - 120}{3} - 25 = 35\ \mathrm{mm}
26.3.2
✓ OK · 90%InputsResults

Scope, assumptions and limitations

  • Valid for sagging moments with the flange in compression. Hogging moments at supports should be designed as rectangular sections of width bw.
  • For xu > Df, IS 456 G-2.2 is used with yf = Df when Df/xu ≤ 0.43, else yf = 0.15 xu + 0.65 Df (≤ Df). Mu,lim uses the Df/d ≤ 0.2 criterion of G-2.2.1.