ULS flexural design of T-beam and L-beam (flanged sections)
Effective flange width and limit state flexural design of monolithic T- and L-beams: neutral axis in the flange or web, limiting moment of the flanged section and required tension reinforcement.
References:cl. 23.1.2cl. 38.1Annex G-2.1Annex G-2.2
IndianCodeApplied — calculation report
| Calculation | ULS flexural design of T-beam and L-beam (flanged sections) |
|---|---|
| Project | — |
| Engineer | — |
| Reference | — |
| Date |
Inputs
| Beam type | T-beam (slab on both sides) |
|---|---|
| Web width | 300 mm |
| Overall depth | 600 mm |
| Flange (slab) thickness | 120 mm |
| Effective cover to tension steel | 60 mm |
| Distance between points of zero moment | 6 m |
| Actual flange width available | 2000 mm |
| Concrete grade | M25 |
| Steel grade | Fe 500 (HYSD) |
| Factored sagging moment | 400 kN m |
| Tension bars — number | 4 |
| Tension bars — diameter | 25 mm |
Design is adequateGoverning: (cl. G-2)
90%max. utilisation
Effective flange width
2000 mm
Limiting moment
1355.5 kN·m
Required tension steel
1761 mm²
Neutral axis depth
42.6 mm
Moment capacity (provided)
444.2 kN·m
Design checks 5
| Check | Clause | Demand | Limit | Utilisation |
|---|---|---|---|---|
| G-2 | 400.0 kN·m | 444.2 kN·m | 90%OK | |
| G-2 | 1963.5 mm² | 1761.1 mm² | 90%OK | |
| 26.5.1.1(b) | 1963.5 mm² | 7200.0 mm² | 27%OK | |
| 26.3.2(a) | 35.0 mm | 25.0 mm | 71%OK | |
| 26.3.3(a), Table 15 | 35.0 mm | 150.0 mm | 23%OK |
| Bars | Area (mm²) | Clear spacing (mm) | Single layer |
|---|---|---|---|
| 16 – Ø12 | 1810 | 0 | ✕ too congested |
| 9 – Ø16 | 1810 | 7 | ✕ too congested |
| 6 – Ø20 | 1885 | 16 | ✕ too congested |
| 4 – Ø25 | 1963 | 35 | ✓ fits |
| 3 – Ø28 | 1847 | 62 | ✓ fits |
| 3 – Ø32 | 2413 | 58 | ✓ fits |
Required area 1761 mm². Clear spacing limits: ≥ max(φ, 25 mm) and ≤ 150 mm (Table 15).
Detailed calculation
Effective flange width
2
23.1.2
23.1.2
Limiting moment of the flanged section
3
38.1
G-2.2.1
G-2.2.1
Required tension reinforcement
5
G-2.1
Mu ≤ Mu,Df: neutral axis lies within the flange — design as rectangular section of width bf.
G-1.1(b)
26.5.1.1(a)
Moment capacity of provided reinforcement
2
38.1
G-2
Bar spacing in the web (detailing)
1
26.3.2
Scope, assumptions and limitations
- Valid for sagging moments with the flange in compression. Hogging moments at supports should be designed as rectangular sections of width bw.
- For xu > Df, IS 456 G-2.2 is used with yf = Df when Df/xu ≤ 0.43, else yf = 0.15 xu + 0.65 Df (≤ Df). Mu,lim uses the Df/d ≤ 0.2 criterion of G-2.2.1.