Quality assurance & verification

The calculation engine is checked against values tabulated in the codes and their design aids. The same benchmarks run as automated tests on every change. Tabulated values are rounded, so each comparison has a tolerance matching the precision of the source table.

Benchmarks
51
Within tolerance
51

IS 456 — design shear strength τc (MPa)

CaseSourceReferenceComputedDifferenceResult
M20, pt = 0.15%IS 456:2000 Table 190.28000.28750.0075OK
M20, pt = 0.5%IS 456:2000 Table 190.48000.4785-0.0015OK
M20, pt = 1%IS 456:2000 Table 190.62000.62250.0025OK
M20, pt = 2%IS 456:2000 Table 190.79000.7851-0.0049OK
M20, pt = 3%IS 456:2000 Table 190.82000.82140.0014OK
M25, pt = 0.25%IS 456:2000 Table 190.36000.36480.0048OK
M25, pt = 0.75%IS 456:2000 Table 190.57000.57480.0048OK
M25, pt = 1.5%IS 456:2000 Table 190.74000.74230.0023OK
M25, pt = 2.5%IS 456:2000 Table 190.88000.8778-0.0022OK
M30, pt = 0.5%IS 456:2000 Table 190.50000.4967-0.0033OK
M30, pt = 1.25%IS 456:2000 Table 190.71000.71340.0034OK
M30, pt = 3%IS 456:2000 Table 190.96000.96160.0016OK
M40, pt = 1%IS 456:2000 Table 190.68000.6767-0.0033OK
M40, pt = 3%IS 456:2000 Table 191.0101.0130.0028OK

IS 456 — limiting depth of neutral axis

CaseSourceReferenceComputedDifferenceResult
Fe 415, xu,max/dIS 456 cl. 38.1 Note0.48000.4791-0.0009OK
Fe 500, xu,max/dIS 456 cl. 38.1 Note0.46000.4560-0.0040OK

IS 456 — limiting moment Mu,lim/(fck b d²)

CaseSourceReferenceComputedDifferenceResult
Fe 250SP 16 Table C0.14800.14830.0003OK
Fe 415SP 16 Table C0.13800.1380-0.0000OK
Fe 500SP 16 Table C0.13300.13360.0006OK

IS 456 — stress in compression steel fsc (MPa)

CaseSourceReferenceComputedDifferenceResult
Fe 415, d′/d = 0.05SP 16 Table F355.0355.30.2650OK
Fe 415, d′/d = 0.1SP 16 Table F353.0352.1-0.8837OK
Fe 415, d′/d = 0.15SP 16 Table F342.0342.70.6758OK
Fe 415, d′/d = 0.2SP 16 Table F329.0329.30.2510OK
Fe 500, d′/d = 0.05SP 16 Table F424.0424.10.0925OK
Fe 500, d′/d = 0.1SP 16 Table F412.0412.10.0906OK
Fe 500, d′/d = 0.15SP 16 Table F395.0395.80.8263OK
Fe 500, d′/d = 0.2SP 16 Table F370.0371.81.829OK

IS 456 — development length (×φ)

CaseSourceReferenceComputedDifferenceResult
M20, Fe 415, tensionSP 16 Table 6547.00047.0120.0117OK
M20, Fe 415, compressionSP 16 Table 6537.60037.6090.0094OK
M25, Fe 500, tensionLd = φ·0.87fy/(4·1.6τbd)48.50048.5490.0491OK

IS 456 — compression steel deflection factor kc

CaseSourceReferenceComputedDifferenceResult
pc = 1.0%IS 456 Fig. 51.2501.2500.0000OK
pc = 3.0%IS 456 Fig. 51.5001.5000.0000OK

IS 800 — design compressive stress fcd, fy = 250 MPa (MPa)

CaseSourceReferenceComputedDifferenceResult
Buckling class a, KL/r = 10IS 800:2007 Table 9(a)227.0227.30.2727OK
Buckling class a, KL/r = 100IS 800:2007 Table 9(a)132.0131.5-0.4647OK
Buckling class c, KL/r = 100IS 800:2007 Table 9(c)107.0107.00.0253OK

IS 6403 — bearing capacity factors

CaseSourceReferenceComputedDifferenceResult
φ = 0°, NcIS 6403:1981 Table 15.1405.1400.0000OK
φ = 20°, NcIS 6403:1981 Table 114.83014.8350.0047OK
φ = 20°, NqIS 6403:1981 Table 16.4006.399-0.0006OK
φ = 20°, NγIS 6403:1981 Table 15.3905.386-0.0037OK
φ = 30°, NcIS 6403:1981 Table 130.14030.140-0.0004OK
φ = 30°, NqIS 6403:1981 Table 118.40018.4010.0011OK
φ = 30°, NγIS 6403:1981 Table 122.40022.4020.0025OK
φ = 40°, NcIS 6403:1981 Table 175.31075.3130.0031OK
φ = 40°, NqIS 6403:1981 Table 164.20064.195-0.0048OK
φ = 40°, NγIS 6403:1981 Table 1109.4109.40.0005OK

IS 1893 — spectral acceleration Sa/g

CaseSourceReferenceComputedDifferenceResult
Medium soil, T = 1.0 sIS 1893 (Part 1):2016 cl. 6.4.21.3601.3600.0000OK
Soft soil, T = 2.0 sIS 1893 (Part 1):2016 cl. 6.4.20.83500.83500.0000OK

Steel sections — plastic modulus Zpz (cm³)

CaseSourceReferenceComputedDifferenceResult
ISMB 300SP 6(1) / IS 800 Annex steel tables651.7653.41.639OK
ISMB 400SP 6(1) / IS 800 Annex steel tables1176.21177.91.722OK
ISMB 500SP 6(1) / IS 800 Annex steel tables2074.72078.03.306OK
ISMB 600SP 6(1) / IS 800 Annex steel tables3510.63516.05.353OK

Other quality measures

  • Every tool is executed with its default inputs in the test suite to make sure it produces finite results without errors.
  • Steel section dimensions are checked for consistency against the catalogue area and second moment of area of each section.
  • Internal consistency checks: flanged beams reduce to rectangular design when the neutral axis lies in the flange; P–M interaction curves are monotonic.
  • Found a discrepancy? Every calculation link encodes its inputs — share the link with the issue so it can be reproduced exactly.