Concrete testing

Ultrasonic pulse velocity — velocity, quality grading and crack depth

Converts UPV transit times to pulse velocity at each test location, grades concrete quality to IS 516 (Part 5/Sec 1), flags doubtful zones, checks whether rebound hammer strength estimates are valid, and estimates crack depth by the indirect method.

References:IS 516 (Part 5/Sec 1)IS 516 (Part 5/Sec 4)IS 13311 (Part 1)
Results meet the acceptance criteriaGoverning: (cl. IS 516 (Part 5/Sec 1))
89%max. utilisation
Report details
Mean velocity VV
4.433 km/s
Lowest velocity
3.922 km/s
Doubtful locations
0
Overall quality
Good

Design checks 1

CheckClauseDemandLimitUtilisation
IS 516 (Part 5/Sec 1)3.922 km/s3.500 km/s89%OK
Pulse velocity by location
01234563.43.63.844.24.44.64.8LocationV (km/s)
  • Velocity
  • Good limit
  • Excellent limit
Velocity at each location
LocationT (µs)V (km/s)Quality
164.24.673Excellent
266.84.491Good
363.54.724Excellent
471.94.172Good
565.04.615Excellent
676.53.922Good

Detailed calculation

Pulse velocity

1
V=LT=300 mmT (μs)V = \dfrac{L}{T} = \dfrac{300\ \mathrm{mm}}{T\ (\mu s)}
IS 516 (Part 5/Sec 1)

Quality grading

2

IS 516 (Part 5/Sec 1) as amended, grade up to M25: above 4.5 km/s Excellent; 3.5–4.5 Good; below 3.5 Doubtful.

All locations ≥ 3.5 km/s: rebound hammer strength estimates can be considered valid at these locations (IS 516 Part 5/Sec 4).

IS 516 (Part 5/Sec 4)
✓ OK · 89%InputsResults

Scope, assumptions and limitations

  • UPV grades concrete quality and uniformity only — it must not be used to estimate the grade of concrete.
  • Indirect (surface) readings are typically lower than direct readings; use them for comparison and crack studies rather than for grading where direct access is possible.
  • Readings parallel and close to reinforcement overestimate velocity; choose paths that avoid bars.