Concrete testing

Load test on a slab or beam — test load and acceptance to IS 456

Works out the test load (full dead load plus 1.25 × imposed load) and evaluates the measured deflections against the IS 456 criteria: maximum deflection limit 40l²/D, 75% recovery within 24 hours, and 80% recovery on a repeated test.

References:IS 456 cl. 17.6
Results meet the acceptance criteriaGoverning: (cl. 17.6(a))
93%max. utilisation
Report details
Test load to apply wapplyw_{apply}
5.25 kN/m²
Deflection limit 40l²/D
5.40 mm
Recovery
80.6 %
Outcome
Acceptable

Design checks 1

CheckClauseDemandLimitUtilisation
17.6(a)80.6 %75.0 %93%OK

Detailed calculation

Test load

2
wtest=g+1.25 q=5.25+1.25×3.00=9.00 kN/m2w_{test} = g + 1.25\,q = 5.25 + 1.25 \times 3.00 = 9.00\ \mathrm{kN/m^{2}}
17.6
wapply=(g−g0)+1.25 q=5.25 kN/m2≈535 kg/m2w_{apply} = (g - g_0) + 1.25\,q = 5.25\ \mathrm{kN/m^{2}} \approx 535\ \mathrm{kg/m^{2}}
17.6

Deflection criteria

2
Δlim=40 l2D=40×4.502150=5.40 mm\Delta_{lim} = \dfrac{40\,l^2}{D} = \dfrac{40 \times 4.50^2}{150} = 5.40\ \mathrm{mm}
17.6(b)
Recovery=Δmax−ΔresΔmax=7.20−1.407.20=80.6%\text{Recovery} = \dfrac{\Delta_{max} - \Delta_{res}}{\Delta_{max}} = \dfrac{7.20 - 1.40}{7.20} = 80.6\%
17.6(a)
✓ OK · 93%InputsResults

Scope, assumptions and limitations

  • Carry out the test after 28 days, with safety props set just clear of the member and deflections measured from an independent reference frame.
  • Correct deflection readings for support settlement and record temperature; load the member in increments and watch for distress.