Concrete testing: IS 456, IS 516, IS 1199

Quality control and assessment: cube acceptance, core tests, UPV, rebound hammer and load tests, with a guide to every common test.

Comparable Eurocode: EN 206 / EN 13791

Calculator

Cube test acceptance

Evaluates 28-day cube results: test result per sample (mean of 3 cubes, ±15% rule), groups of four non-overlapping consecutive results against the Table 11 mean criterion, individual results, statistics and the number of samples required for the quantity cast.

Clauses IS 456 cl. 15.2, 15.4, 16.1, Table 8
Calculator

Core test evaluation

Converts core crushing loads to core strength, corrects for length/diameter ratio, converts to equivalent cube strength and checks the IS 456 acceptance criterion (average ≥ 85% and each core ≥ 75% of the specified cube strength).

Clauses IS 516 (Part 4), IS 456 cl. 17.4
Calculator

UPV quality grading

Converts UPV transit times to pulse velocity at each test location, grades concrete quality to IS 516 (Part 5/Sec 1), flags doubtful zones, checks whether rebound hammer strength estimates are valid, and estimates crack depth by the indirect method.

Clauses IS 516 (Part 5/Sec 1), IS 516 (Part 5/Sec 4), IS 13311 (Part 1)
Calculator

Rebound hammer analysis

Reduces the rebound numbers of a test area (median, mean, scatter and rejection of an unreliable set) and estimates in-situ strength from a calibration line fitted to paired rebound and core/cube strengths of the same concrete.

Clauses IS 516 (Part 5/Sec 4), EN 12504-2 (data reduction), EN 13791 (calibration)
Calculator

Load test evaluation

Works out the test load (full dead load plus 1.25 × imposed load) and evaluates the measured deflections against the IS 456 criteria: maximum deflection limit 40l²/D, 75% recovery within 24 hours, and 80% recovery on a repeated test.

Clauses IS 456 cl. 17.6