Concrete testing

Concrete core test evaluation — equivalent cube strength and acceptance

Converts core crushing loads to core strength, corrects for length/diameter ratio, converts to equivalent cube strength and checks the IS 456 acceptance criterion (average ≥ 85% and each core ≥ 75% of the specified cube strength).

References:IS 516 (Part 4)IS 456 cl. 17.4
Results meet the acceptance criteriaGoverning: (cl. 17.4.3)
72%max. utilisation
Report details
Average equivalent cube strength
29.63 MPa
As % of fck
118.5 %
Lowest core
28.19 MPa
Cores tested
3

Design checks 2

CheckClauseDemandLimitUtilisation
17.4.329.6 MPa21.3 MPa72%OK
17.4.328.2 MPa18.8 MPa67%OK
Core results
Cored (mm)l (mm)l/dLoad (kN)fcore (MPa)k (l/d)Equivalent cube (MPa)≥ 75% fck
1941882.00165.023.781.00029.72✓
2941801.91158.022.770.99128.19✓
3941902.02172.024.781.00030.98✓

Detailed calculation

Core strengths

1
fcore=Pπd2/4,k=0.11 ld+0.78,feq,cube=1.25 k fcoref_{core} = \dfrac{P}{\pi d^2 / 4},\qquad k = 0.11\,\dfrac{l}{d} + 0.78,\qquad f_{eq,cube} = 1.25\,k\,f_{core}
IS 516

Acceptance — IS 456 cl. 17.4.3

2
fˉeq=29.63 MPa≥0.85 fck=21.25 MPa\bar f_{eq} = 29.63\ \mathrm{MPa} \ge 0.85\,f_{ck} = 21.25\ \mathrm{MPa}
17.4.3
feq,min=28.19 MPa≥0.75 fck=18.75 MPaf_{eq,min} = 28.19\ \mathrm{MPa} \ge 0.75\,f_{ck} = 18.75\ \mathrm{MPa}
17.4.3
✓ OK · 72%InputsResults

Scope, assumptions and limitations

  • The l/d correction 0.11n + 0.78 and the cylinder-to-cube factor 1.25 are the widely used relations of IS 516; IS 516 (Part 4):2018 also gives factors for core diameter and moisture condition — apply them where your specification requires.
  • Cores with l/d below 1 should not be tested. Cores containing reinforcement, or with large voids, give unreliable results.