Rebound hammer — data reduction and strength estimate from a site calibration
Reduces the rebound numbers of a test area (median, mean, scatter and rejection of an unreliable set) and estimates in-situ strength from a calibration line fitted to paired rebound and core/cube strengths of the same concrete.
References:IS 516 (Part 5/Sec 4)cl. EN 12504-2 (data reduction)cl. EN 13791 (calibration)
IndianCodeApplied — calculation report
| Calculation | Rebound hammer — data reduction and strength estimate from a site calibration |
|---|---|
| Project | — |
| Engineer | — |
| Reference | — |
| Date |
Inputs
| Rebound numbers in one test area | 34, 36, 33, 35, 37, 34, 32, 36, 35, 38 |
|---|---|
| Calibration pairs: rebound number, strength (MPa) | 28, 22.5; 32, 26.8; 35, 30.1; 38, 34.2; 41, 38.0 |
Results meet the acceptance criteriaGoverning: (cl. EN 12504-2)
0%max. utilisation
Estimated strength
30.6 MPa
Correlation R²
0.997
Median rebound number
35.0
Mean rebound number
35.0
Scatter (std. dev.)
1.83
Design checks 1
| Check | Clause | Demand | Limit | Utilisation |
|---|---|---|---|---|
| EN 12504-2 | 0.000 % | 20.0 % | 0%OK |
- Calibration data
- Fitted line
Detailed calculation
Rebound readings
2
EN 12504-2
Calibration line
2
EN 13791
Estimated in-situ strength
2
Scope, assumptions and limitations
- There is no universal rebound–strength curve; manufacturer curves can be badly in error. Calibrate against cores or cubes of the concrete being assessed.
- Strength estimates are valid only where UPV shows good quality concrete (≥ 3.5 km/s up to M25, ≥ 3.75 km/s above M25).
- The set-rejection rule (more than 20% of readings differing from the median by more than 6 units) follows EN 12504-2.