Ultrasonic pulse velocity (UPV) test
Measures the speed of an ultrasonic pulse through concrete to assess homogeneity, voids, honeycombing, cracks and quality grading.
Standards:IS 516 (Part 5/Sec 1):2018 with Amendment 1 (supersedes IS 13311 Part 1)
Equipment
- UPV instrument with pulse generator and timer (resolution 0.1 µs)
- Transmitting and receiving transducers (typically 54 kHz)
- Reference calibration bar
- Coupling gel/grease
- Measuring tape
Procedure
- Zero the instrument with the reference bar.
- Prepare smooth test points and apply couplant. Prefer the direct (cross-probing) method with transducers on opposite faces; use semi-direct or indirect (surface) methods only where access is limited.
- Press the transducers firmly and record the stable transit time T; measure the path length L.
- Avoid paths along reinforcement bars, which carry the pulse faster.
- For crack depth (indirect method), take readings with transducers placed symmetrically at distance x either side of the crack (Tc) and on sound concrete at the same spacing (Ts).
Calculation
estimate of crack depth from the indirect method
Results and acceptance criteria
- Quality grading (IS 516 Part 5/Sec 1, as amended): grades up to M25 — above 4.5 km/s Excellent, 3.5–4.5 Good, below 3.5 Doubtful; grades above M25 — above 4.5 Excellent, 3.75–4.5 Good, below 3.75 Doubtful.
- Doubtful zones need further investigation (cores). UPV grading must not be used to estimate the concrete grade.
This page summarises the procedure for site and laboratory use. Follow the current edition of the cited standards (with amendments) and the project specification, which govern.