Non-destructive testing (NDT)

Rebound hammer test (Schmidt hammer)

Measures surface hardness to assess the uniformity of concrete and, with a site calibration, to estimate compressive strength.

Standards:IS 516 (Part 5/Sec 4):2020 (supersedes IS 13311 Part 2)IS 516 (Part 5/Sec 1) — combined use with UPV
Evaluate your results → Rebound hammer analysis: Reduces the rebound numbers of a test area (median, mean, scatter and rejection of an unreliable set) and estimates in-situ strength from a calibration line fitted to paired rebound and core/cube strengths of the same concrete.

Equipment

  • Rebound hammer (type N, impact energy 2.207 N·m) with test anvil for calibration
  • Carborundum stone for surface preparation
  • Chalk/grid template, data sheet

Procedure

  1. Check the hammer on its calibration anvil before and after use.
  2. Select test areas on smooth, dry, formed surfaces at least 25 mm from edges; grind off plaster, laitance and loose material.
  3. Hold the hammer perpendicular to the surface and press until the plunger releases; read the rebound number. Take about 10–12 readings per test area at points at least 25 mm apart, not on the same spot twice.
  4. Note the hammer orientation (horizontal, upward, downward) and apply the manufacturer's correction where needed.
  5. Use the median or mean after discarding abnormal readings; estimate strength only from a correlation established with cores or cubes of the same concrete.

Results and acceptance criteria

  • Rebound number reflects only the outer 30–50 mm; carbonation, moisture, surface finish and aggregate type all affect it.
  • The rebound estimate of in-situ strength is considered valid only when the UPV indicates good quality concrete (velocity ≥ 3.5 km/s for grades up to M25, ≥ 3.75 km/s above M25) — see the UPV test.
  • Accuracy of strength estimates from rebound alone is no better than about ±25%.

This page summarises the procedure for site and laboratory use. Follow the current edition of the cited standards (with amendments) and the project specification, which govern.