Bolt group in shear and tension — bearing type and friction grip (HSFG) bolts
Design strength of bolts per IS 800: shear on threads and shank, bearing on plates with kb, reductions for long joints and large grip, tension capacity, combined shear and tension interaction, and slip resistance of HSFG bolts.
References:cl. 10.2cl. 10.3.2cl. 10.3.3cl. 10.3.4cl. 10.3.5cl. 10.3.6cl. 10.4.3cl. 10.4.5cl. 10.4.6
IndianCodeApplied — calculation report
| Calculation | Bolt group in shear and tension — bearing type and friction grip (HSFG) bolts |
|---|---|
| Project | — |
| Engineer | — |
| Reference | — |
| Date |
Inputs
| Bolt type | Bearing type (black / HSFG in bearing) |
|---|---|
| Property class | Class 4.6 (fub = 400 MPa) |
| Bolt diameter | M20 |
| Number of bolts | 6 |
| Shear planes through threads | 1 |
| Shear planes through shank | 0 |
| Least total thickness bearing in one direction | 10 mm |
| Ultimate stress of plate | 410 MPa |
| End distance | 40 mm |
| Pitch | 60 mm |
| Joint length (first to last bolt) | 120 mm |
| Grip length | 20 mm |
| Factored shear on group | 250 kN |
| Factored tension per bolt | 0 kN |
Design is adequateGoverning: (cl. 10.3.2)
92%max. utilisation
Design strength per bolt (shear)
45.26 kN
Group shear capacity
271.6 kN
Design tension per bolt
70.56 kN
Shear per bolt
41.67 kN
Design checks 3
| Check | Clause | Demand | Limit | Utilisation |
|---|---|---|---|---|
| 10.3.2 | 41.7 kN | 45.3 kN | 92%OK | |
| 10.2.2 | 60.0 mm | 50.0 mm | 83%OK | |
| 10.2.4.2 | 40.0 mm | 33.0 mm | 83%OK |
Detailed calculation
Bolt properties
1
IS 1367, Table 19
Shear capacity of bolt
1
10.3.3
Bearing capacity on plate
3
10.3.4
10.3.4
10.3.2
Tension capacity of bolt
1
10.3.5
Bolt group
1
Scope, assumptions and limitations
- Net tensile stress area Anb is taken as the tensile stress area of the bolt (≈ 0.78 × shank area).
- Slip factors depend on the faying surface treatment — confirm against IS 800 Table 20 for the specified surface.
- The packing plate reduction βpk (cl. 10.3.3.3) is not applied.