Materials (before concreting)

Water for mixing and curing

Checks that mixing water does not contain harmful amounts of acids, alkalis, salts, sugar or organic matter.

Standards:IS 456 cl. 5.4IS 3025 (various parts) — chemical analysis

Equipment

  • pH meter
  • Laboratory chemical analysis (solids, chlorides, sulphates)
  • Cube moulds and Vicat apparatus for comparative tests

Procedure

  1. Collect a clean sample of the proposed water in a clean container.
  2. Determine pH, organic and inorganic solids, sulphates and chlorides by IS 3025 methods.
  3. Make comparative cubes and setting time tests with the site water and with distilled water.

Results and acceptance criteria

  • pH not less than 6 (IS 456 cl. 5.4).
  • Permissible limits (mg/l): organic solids 200, inorganic solids 3000, sulphates (SO₃) 400, chlorides (Cl) 2000 for plain concrete and 500 for reinforced concrete.
  • 28-day cube strength with the site water ≥ 90% of cubes made with distilled water; initial setting time not less than 30 min and not differing by more than ± 30 min.

This page summarises the procedure for site and laboratory use. Follow the current edition of the cited standards (with amendments) and the project specification, which govern.