Fresh concrete

Sampling of fresh concrete

Obtaining a representative sample at the point of discharge for all fresh concrete tests and for making strength specimens.

Standards:IS 1199 (Part 1):2018IS 456 cl. 15.2 — sampling frequency
Evaluate your results → Cube test acceptance: Evaluates 28-day cube results

Equipment

  • Clean, non-absorbent scoop and bucket or wheelbarrow
  • Mixing tray
  • Thermometer

Procedure

  1. Take at least three increments at regular intervals during discharge of the batch (not from the very first or last part of the load) and combine them.
  2. Remix the composite sample on the tray and protect it from sun, wind and rain.
  3. Start the fresh concrete tests promptly (within about 5 minutes) and complete the moulding of specimens within about 15 minutes of sampling.

Results and acceptance criteria

  • Sampling frequency for strength (IS 456 cl. 15.2.2): 1–5 m³: 1 sample; 6–15 m³: 2; 16–30 m³: 3; 31–50 m³: 4; above 50 m³: 4 plus one for each additional 50 m³ or part.
  • At least one sample from each shift; each sample normally gives three cubes per test age.

This page summarises the procedure for site and laboratory use. Follow the current edition of the cited standards (with amendments) and the project specification, which govern.