Hardened concrete — strength tests

Compressive strength — cube test

The primary test for acceptance of concrete: 150 mm cubes are made at site, cured and crushed at 7 and 28 days.

Standards:IS 1199 (Part 5):2018 — making and curing specimensIS 516 (Part 1/Sec 1):2021 — testing (supersedes IS 516:1959)IS 456 cl. 15, 16 — sampling and acceptance
Evaluate your results → Cube test acceptance: Evaluates 28-day cube results

Equipment

  • Cast-iron or steel cube moulds 150 mm (100 mm for aggregate ≤ 20 mm only where permitted), oiled
  • Tamping bar (16 mm, 600 mm, rounded) or vibrating table/needle
  • Curing tank with water at 27 ± 2 °C
  • Compression testing machine (2000 kN) with calibrated gauge/load cell and a spherically seated platen
  • Balance, ruler, identification marker

Procedure

  1. Fill moulds in layers about 50 mm deep. Compact each layer by not less than 35 strokes of the tamping bar (150 mm cubes) or by vibration until no more air bubbles appear.
  2. Finish the top with a trowel and mark the cube. Store at 27 ± 2 °C and ≥ 90% relative humidity, covered, for 24 hours.
  3. Demould and transfer to the curing tank at 27 ± 2 °C until testing.
  4. Test in a saturated condition: wipe, measure and weigh the cube, place it with the cast faces at the sides (load on moulded faces) and centre it on the platen.
  5. Apply load without shock and increase it continuously at the rate specified in IS 516 (Part 1/Sec 1):2021 (14 N/mm² per minute under the former IS 516:1959) until failure; record the maximum load and the failure pattern.

Calculation

fc=PmaxA,test result=mean of 3 cubesf_c = \dfrac{P_{max}}{A},\qquad \text{test result} = \text{mean of 3 cubes}

Results and acceptance criteria

  • A test result is the mean of three specimens; individual results should be within ±15% of the mean, otherwise the result is invalid (IS 456 cl. 15.4).
  • Acceptance (IS 456 cl. 16, Table 11): based on the mean of groups of four non-overlapping consecutive results and on individual results — use the cube acceptance calculator.
  • 7-day strength is typically about 65–70% of the 28-day strength for OPC concrete (indicative only — acceptance is at 28 days).
  • Satisfactory failure: four faces cracked roughly equally with an hour-glass shape. Unusual failures (one-sided, tensile) suggest eccentric loading or poor compaction.

This page summarises the procedure for site and laboratory use. Follow the current edition of the cited standards (with amendments) and the project specification, which govern.