Aggregates — specific gravity, water absorption and bulking of sand
Specific gravity and absorption are needed for mix design and for correcting batch water; bulking of moist sand corrects volume batching.
Standards:IS 2386 (Part 3)
Equipment
- Wire basket and water tank with balance for weighing in water (coarse aggregate)
- Pycnometer or 1 l flask (fine aggregate)
- Oven, absorbent cloth, airtight container
- Measuring cylinder (bulking)
Procedure
- Soak washed aggregate for 24 hours, weigh it in water (B), surface-dry it with a cloth to the saturated-surface-dry state and weigh (A), then oven-dry and weigh (C).
- Bulking: fill a cylinder with moist sand loosely, note the height h₁; flood with water, stir and note the settled height h₂.
Calculation
Results and acceptance criteria
- Typical specific gravity of natural aggregates 2.6–2.8; water absorption usually below 2% (IS 383 limits absorption for some uses — check the project specification).
- Moist sand can bulk by 20–40%; correct volume batching accordingly.
This page summarises the procedure for site and laboratory use. Follow the current edition of the cited standards (with amendments) and the project specification, which govern.