Fresh concrete

Setting time of concrete (penetration resistance)

Determines the initial and final setting times of the concrete itself (affected by admixtures and temperature), useful for planning finishing and cold joints.

Standards:IS 1199 (Part 7):2018ASTM C403 (equivalent method)

Equipment

  • 4.75 mm sieve to wet-sieve mortar
  • Container
  • Penetration resistance apparatus with needles of different bearing areas

Procedure

  1. Sieve the mortar from a concrete sample and place it in the container.
  2. At regular intervals, push a needle 25 mm into the mortar in about 10 s and record the force.
  3. Plot penetration resistance (force / needle area) against elapsed time from the first contact of cement and water.

Results and acceptance criteria

  • Initial set: penetration resistance 3.5 MPa; final set: 27.6 MPa.

This page summarises the procedure for site and laboratory use. Follow the current edition of the cited standards (with amendments) and the project specification, which govern.