Durability and corrosion assessment

Rapid chloride permeability test (RCPT)

Rates the resistance of concrete to chloride ion penetration from the electrical charge passed through a slice in 6 hours.

Standards:ASTM C1202

Equipment

  • RCPT cells with NaCl and NaOH solutions
  • 60 V DC power supply and data logger
  • Vacuum saturation apparatus
  • Slices 50 mm thick from 100 mm cores or cylinders

Procedure

  1. Vacuum-saturate the 50 mm slice, seal it between the two cells (3% NaCl on one side, 0.3 N NaOH on the other).
  2. Apply 60 V DC for 6 hours and integrate the current to obtain the charge passed in coulombs.

Results and acceptance criteria

  • Charge passed (ASTM C1202): > 4000 C High; 2000–4000 Moderate; 1000–2000 Low; 100–1000 Very low; < 100 Negligible chloride ion penetrability.

This page summarises the procedure for site and laboratory use. Follow the current edition of the cited standards (with amendments) and the project specification, which govern.