Compacting factor test
Measures workability of low-workability concrete (where the slump test is insensitive) as the degree of compaction achieved by a standard amount of work.
Standards:IS 1199 (Part 2):2018
Equipment
- Compacting factor apparatus: two conical hoppers with trap doors above a cylinder (150 mm dia., 300 mm high)
- Balance, tamping rod or vibrator
- Trowels
Procedure
- Fill the upper hopper gently, open its trap door so the concrete falls into the lower hopper, then open the lower door to fill the cylinder.
- Strike off the excess and weigh the partially compacted concrete (W₁).
- Empty the cylinder, refill it with the same concrete in layers fully compacted by rodding or vibration, and weigh (W₂).
Calculation
Results and acceptance criteria
- Typical values: 0.75–0.80 very low workability (pavements with pavers), 0.85–0.92 low to medium, above 0.92 high workability.
This page summarises the procedure for site and laboratory use. Follow the current edition of the cited standards (with amendments) and the project specification, which govern.