IS 875

Design wind speed, wind pressure and wall pressures on buildings

Design wind speed Vz = Vb k1 k2 k3 k4 at each height, wind pressure pz = 0.6 Vz², design pressure pd = Kd Ka Kc pz, the height profile of a building, and net wall pressures using external (Table 5) and internal pressure coefficients.

References:cl. 5.3cl. 6.3cl. 6.3.1cl. 6.3.2cl. 6.3.3cl. 6.3.4cl. 7.2cl. 7.3Table 1Table 2Table 4Table 5Annex A
Report details
Basic wind speed VbV_b
47 m/s
Design wind speed at h VzV_z
52.64 m/s
Wind pressure at h pzp_z
1.663 kN/m²
Design wind pressure at h pdp_d
1.496 kN/m²
k2 at h k2k_2
1.120
Design wind pressure pd with height
00.20.40.60.811.21.41.6051015202530pd (kN/m²)z (m)
Net design wall pressures at roof level, F = (Cpe − Cpi) pd
FaceCpeCpe − (+Cpi)Cpe − (−Cpi)p+Cpi (kN/m²)p−Cpi (kN/m²)
A (windward, θ = 0°)0.70.500.900.7481.347
B (leeward, θ = 0°)-0.25-0.45-0.05-0.673-0.075
C (side, θ = 0°)-0.6-0.80-0.40-1.197-0.599
D (side, θ = 0°)-0.6-0.80-0.40-1.197-0.599

Positive = pressure towards the surface, negative = suction. Use local Cpe for cladding near corners.

Wind pressure profile
Height z (m)k2Vz (m/s)pz (kN/m²)pd (kN/m²)
0–10.01.00047.001.3251.193
15.01.05049.351.4611.315
20.01.07050.291.5171.366
30.01.12052.641.6631.496

Detailed calculation

Basic wind speed and factors

3
Vb=47 m/s (Delhi)V_b = 47\ \mathrm{m/s}\ (\text{Delhi})
5.2, Annex A
k1=1.000,k3=1.00,k4=1.00k_1 = 1.000,\quad k_3 = 1.00,\quad k_4 = 1.00
6.3.1, 6.3.3, 6.3.4
Kd=0.9,Ka=1.000 (A=10 m2),Kc=1K_d = 0.9,\quad K_a = 1.000\ (A = 10\ \mathrm{m^{2}}),\quad K_c = 1
7.2.1, Table 4, 7.3.3.13

Design wind pressure at roof level z = h = 30 m

4
k2=1.120(terrain category 2)k_2 = 1.120\quad (\text{terrain category } 2)
6.3.2, Table 2
Vz=Vb k1 k2 k3 k4=47×1.000×1.120×1.00×1.00=52.64 m/sV_z = V_b\,k_1\,k_2\,k_3\,k_4 = 47 \times 1.000 \times 1.120 \times 1.00 \times 1.00 = 52.64\ \mathrm{m/s}
6.3
pz=0.6 Vz2=0.6×52.642=1663 N/m2p_z = 0.6\,V_z^2 = 0.6 \times 52.64^2 = 1663\ \mathrm{N/m^{2}}
7.2
pd=Kd Ka Kc pz=1496 N/m2≥0.7 pz=1164⇒pd=1496 N/m2p_d = K_d\,K_a\,K_c\,p_z = 1496\ \mathrm{N/m^{2}} \ge 0.7\,p_z = 1164 \Rightarrow p_d = 1496\ \mathrm{N/m^{2}}
7.2

Wall pressure coefficients

4
hw=1.50,lw=1.50\dfrac{h}{w} = 1.50,\quad \dfrac{l}{w} = 1.50
Table 5

θ = 0° (wind normal to face A): Cpe A = 0.7, B = -0.25, C = -0.6, D = -0.6; local Cpe = -1.1

Table 5

θ = 90°: Cpe A = -0.6, B = -0.6, C = 0.7, D = -0.25

Table 5
Cpi=±0.2C_{pi} = \pm 0.2
7.3.2

Scope, assumptions and limitations

  • Basic wind speeds for cities are from Annex A of IS 875 (Part 3):2015; always confirm with the wind zone map for the exact site.
  • k2 is interpolated linearly in Table 2; for heights below 10 m the 10 m value is used.
  • Tall or dynamically sensitive buildings (height/min. lateral dimension > 5 or natural frequency < 1 Hz) require gust factor (cl. 10) or dynamic analysis.