Design wind speed, wind pressure and wall pressures on buildings
Design wind speed Vz = Vb k1 k2 k3 k4 at each height, wind pressure pz = 0.6 Vz², design pressure pd = Kd Ka Kc pz, the height profile of a building, and net wall pressures using external (Table 5) and internal pressure coefficients.
References:cl. 5.3cl. 6.3cl. 6.3.1cl. 6.3.2cl. 6.3.3cl. 6.3.4cl. 7.2cl. 7.3Table 1Table 2Table 4Table 5Annex A
IndianCodeApplied — calculation report
| Calculation | Design wind speed, wind pressure and wall pressures on buildings |
|---|---|
| Project | — |
| Engineer | — |
| Reference | — |
| Date |
Inputs
| Location | Delhi (47 m/s) |
|---|---|
| Terrain category | Category 2 — open terrain with scattered obstructions 1.5–10 m (airfields, outskirts) |
| Structure class (risk coefficient k1) | All general buildings and structures (50 yr design life) |
| Topography factor | 1 |
| Importance factor for cyclonic region | 1.00 — not in cyclonic region / others |
| Cyclone-affected region (Kd = 1.0) | No |
| Tributary area for Ka | 10 m² |
| Combination factor Kc | 1.0 |
| Building height | 30 m |
| Building width (lesser plan dimension) | 20 m |
| Building length (greater plan dimension) | 30 m |
| Permeability (internal pressure) | Openings < 5% of wall area (±0.2) |
Basic wind speed
47 m/s
Design wind speed at h
52.64 m/s
Wind pressure at h
1.663 kN/m²
Design wind pressure at h
1.496 kN/m²
k2 at h
1.120
| Face | Cpe | Cpe − (+Cpi) | Cpe − (−Cpi) | p+Cpi (kN/m²) | p−Cpi (kN/m²) |
|---|---|---|---|---|---|
| A (windward, θ = 0°) | 0.7 | 0.50 | 0.90 | 0.748 | 1.347 |
| B (leeward, θ = 0°) | -0.25 | -0.45 | -0.05 | -0.673 | -0.075 |
| C (side, θ = 0°) | -0.6 | -0.80 | -0.40 | -1.197 | -0.599 |
| D (side, θ = 0°) | -0.6 | -0.80 | -0.40 | -1.197 | -0.599 |
Positive = pressure towards the surface, negative = suction. Use local Cpe for cladding near corners.
| Height z (m) | k2 | Vz (m/s) | pz (kN/m²) | pd (kN/m²) |
|---|---|---|---|---|
| 0–10.0 | 1.000 | 47.00 | 1.325 | 1.193 |
| 15.0 | 1.050 | 49.35 | 1.461 | 1.315 |
| 20.0 | 1.070 | 50.29 | 1.517 | 1.366 |
| 30.0 | 1.120 | 52.64 | 1.663 | 1.496 |
Detailed calculation
Basic wind speed and factors
3
5.2, Annex A
6.3.1, 6.3.3, 6.3.4
7.2.1, Table 4, 7.3.3.13
Design wind pressure at roof level z = h = 30 m
4
6.3.2, Table 2
6.3
7.2
7.2
Wall pressure coefficients
4
Table 5
θ = 0° (wind normal to face A): Cpe A = 0.7, B = -0.25, C = -0.6, D = -0.6; local Cpe = -1.1
θ = 90°: Cpe A = -0.6, B = -0.6, C = 0.7, D = -0.25
7.3.2
Scope, assumptions and limitations
- Basic wind speeds for cities are from Annex A of IS 875 (Part 3):2015; always confirm with the wind zone map for the exact site.
- k2 is interpolated linearly in Table 2; for heights below 10 m the 10 m value is used.
- Tall or dynamically sensitive buildings (height/min. lateral dimension > 5 or natural frequency < 1 Hz) require gust factor (cl. 10) or dynamic analysis.