IS 875

Limit state load combinations (IS 875-5, IS 456, IS 800, IS 1893)

Generates ultimate and serviceability limit state load combinations with partial safety factors for dead, imposed, wind and earthquake loads, including ±X/±Y directions and the 100% + 30% orthogonal rule for earthquake.

References:IS 456 Table 18IS 800 Table 4IS 875 (Part 5) cl. 8IS 1893 (Part 1) 6.3
Report details
ULS combinations
25
SLS combinations
13
Ultimate limit state — 25 combinations
IDCombinationDLILWXWYEXEY
U11.5(DL + IL)1.51.5————
U21.2(DL + IL ± WL): +Wx1.21.21.2———
U31.2(DL + IL ± WL): −Wx1.21.2-1.2———
U41.2(DL + IL ± WL): +Wy1.21.2—1.2——
U51.2(DL + IL ± WL): −Wy1.21.2—-1.2——
U61.5(DL ± WL): +Wx1.5—1.5———
U71.5(DL ± WL): −Wx1.5—-1.5———
U81.5(DL ± WL): +Wy1.5——1.5——
U91.5(DL ± WL): −Wy1.5——-1.5——
U100.9DL ± 1.5WL: +Wx0.9—1.5———
U110.9DL ± 1.5WL: −Wx0.9—-1.5———
U120.9DL ± 1.5WL: +Wy0.9——1.5——
U130.9DL ± 1.5WL: −Wy0.9——-1.5——
U141.2(DL + IL ± EL): +Ex1.21.2——1.2—
U151.2(DL + IL ± EL): −Ex1.21.2——-1.2—
U161.2(DL + IL ± EL): +Ey1.21.2———1.2
U171.2(DL + IL ± EL): −Ey1.21.2———-1.2
U181.5(DL ± EL): +Ex1.5———1.5—
U191.5(DL ± EL): −Ex1.5———-1.5—
U201.5(DL ± EL): +Ey1.5————1.5
U211.5(DL ± EL): −Ey1.5————-1.5
U220.9DL ± 1.5EL: +Ex0.9———1.5—
U230.9DL ± 1.5EL: −Ex0.9———-1.5—
U240.9DL ± 1.5EL: +Ey0.9————1.5
U250.9DL ± 1.5EL: −Ey0.9————-1.5
Serviceability limit state — 13 combinations
IDCombinationDLILWXWYEXEY
S1DL + IL11————
S2DL ± WL: +Wx1—1———
S3DL ± WL: −Wx1—-1———
S4DL ± WL: +Wy1——1——
S5DL ± WL: −Wy1——-1——
S6DL + 0.8IL ± 0.8WL: +Wx10.80.8———
S7DL + 0.8IL ± 0.8WL: −Wx10.8-0.8———
S8DL + 0.8IL ± 0.8WL: +Wy10.8—0.8——
S9DL + 0.8IL ± 0.8WL: −Wy10.8—-0.8——
S10DL + IL ± EL: +Ex11——1—
S11DL + IL ± EL: −Ex11——-1—
S12DL + IL ± EL: +Ey11———1
S13DL + IL ± EL: −Ey11———-1

Detailed calculation

Partial safety factors

3

DL + IL: 1.5, 1.5 | DL + WL/EL: 1.5 or 0.9 (DL), 1.5 | DL + IL + WL/EL: 1.2, 1.2, 1.2

IS 456 Table 18

Serviceability: DL + IL: 1.0, 1.0 | DL + WL/EL: 1.0, 1.0 | DL + IL + WL/EL: 1.0, 0.8, 0.8

IS 456 Table 18

Seismic weight includes 25% of imposed load (3 kN/m²); imposed load on roof is not included. IS 1893 Table 10.

IS 1893 7.3.1

Scope, assumptions and limitations

  • IS 1893 (Part 1):2016 cl. 6.3.1.2 combinations: 1.5(DL + IL), 1.2(DL + IL ± EL), 1.5(DL ± EL), 0.9DL ± 1.5EL. Wind and earthquake are not combined (cl. 6.3.2.2).
  • IS 800 Table 4: with lateral load, the leading variable action takes 1.2 (or 1.5 without IL) and accompanying imposed load 1.05 / wind 0.6.
  • For IS 456 serviceability combinations with three loads, the variable loads take 0.8.