Limit state load combinations (IS 875-5, IS 456, IS 800, IS 1893)
Generates ultimate and serviceability limit state load combinations with partial safety factors for dead, imposed, wind and earthquake loads, including ±X/±Y directions and the 100% + 30% orthogonal rule for earthquake.
References:IS 456 Table 18IS 800 Table 4IS 875 (Part 5) cl. 8IS 1893 (Part 1) 6.3
IndianCodeApplied — calculation report
| Calculation | Limit state load combinations (IS 875-5, IS 456, IS 800, IS 1893) |
|---|---|
| Project | — |
| Engineer | — |
| Reference | — |
| Date |
Inputs
| Material code | IS 456 — concrete (Table 18) |
|---|---|
| Include wind load (WL) | Yes |
| Include earthquake load (EL) | Yes |
| Apply 100% + 30% orthogonal earthquake rule | No |
| Imposed load intensity (for EQ seismic weight note) | 3 kN/m² |
ULS combinations
25
SLS combinations
13
| ID | Combination | DL | IL | WX | WY | EX | EY |
|---|---|---|---|---|---|---|---|
| U1 | 1.5(DL + IL) | 1.5 | 1.5 | — | — | — | — |
| U2 | 1.2(DL + IL ± WL): +Wx | 1.2 | 1.2 | 1.2 | — | — | — |
| U3 | 1.2(DL + IL ± WL): −Wx | 1.2 | 1.2 | -1.2 | — | — | — |
| U4 | 1.2(DL + IL ± WL): +Wy | 1.2 | 1.2 | — | 1.2 | — | — |
| U5 | 1.2(DL + IL ± WL): −Wy | 1.2 | 1.2 | — | -1.2 | — | — |
| U6 | 1.5(DL ± WL): +Wx | 1.5 | — | 1.5 | — | — | — |
| U7 | 1.5(DL ± WL): −Wx | 1.5 | — | -1.5 | — | — | — |
| U8 | 1.5(DL ± WL): +Wy | 1.5 | — | — | 1.5 | — | — |
| U9 | 1.5(DL ± WL): −Wy | 1.5 | — | — | -1.5 | — | — |
| U10 | 0.9DL ± 1.5WL: +Wx | 0.9 | — | 1.5 | — | — | — |
| U11 | 0.9DL ± 1.5WL: −Wx | 0.9 | — | -1.5 | — | — | — |
| U12 | 0.9DL ± 1.5WL: +Wy | 0.9 | — | — | 1.5 | — | — |
| U13 | 0.9DL ± 1.5WL: −Wy | 0.9 | — | — | -1.5 | — | — |
| U14 | 1.2(DL + IL ± EL): +Ex | 1.2 | 1.2 | — | — | 1.2 | — |
| U15 | 1.2(DL + IL ± EL): −Ex | 1.2 | 1.2 | — | — | -1.2 | — |
| U16 | 1.2(DL + IL ± EL): +Ey | 1.2 | 1.2 | — | — | — | 1.2 |
| U17 | 1.2(DL + IL ± EL): −Ey | 1.2 | 1.2 | — | — | — | -1.2 |
| U18 | 1.5(DL ± EL): +Ex | 1.5 | — | — | — | 1.5 | — |
| U19 | 1.5(DL ± EL): −Ex | 1.5 | — | — | — | -1.5 | — |
| U20 | 1.5(DL ± EL): +Ey | 1.5 | — | — | — | — | 1.5 |
| U21 | 1.5(DL ± EL): −Ey | 1.5 | — | — | — | — | -1.5 |
| U22 | 0.9DL ± 1.5EL: +Ex | 0.9 | — | — | — | 1.5 | — |
| U23 | 0.9DL ± 1.5EL: −Ex | 0.9 | — | — | — | -1.5 | — |
| U24 | 0.9DL ± 1.5EL: +Ey | 0.9 | — | — | — | — | 1.5 |
| U25 | 0.9DL ± 1.5EL: −Ey | 0.9 | — | — | — | — | -1.5 |
| ID | Combination | DL | IL | WX | WY | EX | EY |
|---|---|---|---|---|---|---|---|
| S1 | DL + IL | 1 | 1 | — | — | — | — |
| S2 | DL ± WL: +Wx | 1 | — | 1 | — | — | — |
| S3 | DL ± WL: −Wx | 1 | — | -1 | — | — | — |
| S4 | DL ± WL: +Wy | 1 | — | — | 1 | — | — |
| S5 | DL ± WL: −Wy | 1 | — | — | -1 | — | — |
| S6 | DL + 0.8IL ± 0.8WL: +Wx | 1 | 0.8 | 0.8 | — | — | — |
| S7 | DL + 0.8IL ± 0.8WL: −Wx | 1 | 0.8 | -0.8 | — | — | — |
| S8 | DL + 0.8IL ± 0.8WL: +Wy | 1 | 0.8 | — | 0.8 | — | — |
| S9 | DL + 0.8IL ± 0.8WL: −Wy | 1 | 0.8 | — | -0.8 | — | — |
| S10 | DL + IL ± EL: +Ex | 1 | 1 | — | — | 1 | — |
| S11 | DL + IL ± EL: −Ex | 1 | 1 | — | — | -1 | — |
| S12 | DL + IL ± EL: +Ey | 1 | 1 | — | — | — | 1 |
| S13 | DL + IL ± EL: −Ey | 1 | 1 | — | — | — | -1 |
Detailed calculation
Partial safety factors
3
DL + IL: 1.5, 1.5 | DL + WL/EL: 1.5 or 0.9 (DL), 1.5 | DL + IL + WL/EL: 1.2, 1.2, 1.2
Serviceability: DL + IL: 1.0, 1.0 | DL + WL/EL: 1.0, 1.0 | DL + IL + WL/EL: 1.0, 0.8, 0.8
Seismic weight includes 25% of imposed load (3 kN/m²); imposed load on roof is not included. IS 1893 Table 10.
Scope, assumptions and limitations
- IS 1893 (Part 1):2016 cl. 6.3.1.2 combinations: 1.5(DL + IL), 1.2(DL + IL ± EL), 1.5(DL ± EL), 0.9DL ± 1.5EL. Wind and earthquake are not combined (cl. 6.3.2.2).
- IS 800 Table 4: with lateral load, the leading variable action takes 1.2 (or 1.5 without IL) and accompanying imposed load 1.05 / wind 0.6.
- For IS 456 serviceability combinations with three loads, the variable loads take 0.8.