IS 6403:1981

Bearing capacity of shallow foundations (IS 6403)

Net ultimate and net safe bearing capacity of strip, square, circular and rectangular shallow foundations from soil shear parameters, with shape, depth and inclination factors, water table correction and general or local shear failure.

References:cl. 5.1cl. 5.1.1cl. 5.1.2Table 1Table 2
Report details
Net ultimate bearing capacity qnuq_{nu}
1495.1 kN/m²
Net safe bearing capacity qnsq_{ns}
598.1 kN/m²
Safe load on footing
2392 kN
Nc / Nq / Nγ
30.14 / 18.40 / 22.40
Bearing capacity factors (IS 6403 Table 1)
φ (°)NcNqNγ
05.141.000.00
56.491.570.45
108.342.471.22
1510.983.942.65
2014.836.405.39
2520.7210.6610.88
3030.1418.4022.40
3546.1233.3048.03
4075.3164.20109.41
45133.87134.87271.75
50266.88319.06762.86

Detailed calculation

Soil parameters

1
c=10.00 kN/m2,ϕ=30.00°c = 10.00\ \mathrm{kN/m^{2}},\quad \phi = 30.00°

Bearing capacity factors

2
Nq=eπtan⁡ϕtan⁡2(45°+ϕ2)=18.40N_q = e^{\pi\tan\phi}\tan^2\left(45° + \tfrac{\phi}{2}\right) = 18.40
Table 1
Nc=(Nq−1)cot⁡ϕ=30.14,Nγ=2(Nq+1)tan⁡ϕ=22.40N_c = (N_q - 1)\cot\phi = 30.14,\quad N_\gamma = 2(N_q + 1)\tan\phi = 22.40
Table 1

Shape, depth and inclination factors

4
sc=1.300,sq=1.200,sγ=0.800s_c = 1.300,\quad s_q = 1.200,\quad s_\gamma = 0.800
Table 2
Nϕ=tan⁡2(45°+ϕ/2)=3.000N_\phi = \tan^2(45° + \phi/2) = 3.000
5.1.2.2
dc=1+0.2 DfBNϕ=1.260,dq=dγ=1+0.1 DfBNϕ=1.130d_c = 1 + 0.2\,\dfrac{D_f}{B}\sqrt{N_\phi} = 1.260,\quad d_q = d_\gamma = 1 + 0.1\,\dfrac{D_f}{B}\sqrt{N_\phi} = 1.130
5.1.2.2
ic=iq=(1−α90)2=1.000,iγ=(1−αϕ)2=1.000i_c = i_q = \left(1 - \dfrac{\alpha}{90}\right)^2 = 1.000,\quad i_\gamma = \left(1 - \dfrac{\alpha}{\phi}\right)^2 = 1.000
5.1.2.3

Water table correction

2
W′=1.000(Dw=10 m)W' = 1.000\quad (D_w = 10\ \mathrm{m})
5.1.2.4
q=effective overburden at Df=27.00 kN/m2q = \text{effective overburden at } D_f = 27.00\ \mathrm{kN/m^{2}}

Net ultimate and safe bearing capacity

3
qnu=cNcscdcic+q(Nq−1)sqdqiq+12BγNγsγdγiγW′q_{nu} = c N_c s_c d_c i_c + q(N_q - 1) s_q d_q i_q + \tfrac{1}{2} B \gamma N_\gamma s_\gamma d_\gamma i_\gamma W'
5.1.2
qnu=493.6+637.0+364.5=1495.1 kN/m2q_{nu} = 493.6 + 637.0 + 364.5 = 1495.1\ \mathrm{kN/m^{2}}
5.1.2
qns=qnuFS=1495.12.5=598.1 kN/m2q_{ns} = \dfrac{q_{nu}}{FS} = \dfrac{1495.1}{2.5} = 598.1\ \mathrm{kN/m^{2}}

Scope, assumptions and limitations

  • Water table correction W′ = 0.5 when the water table is at or above the base of the footing, 1.0 at depth ≥ Df + B below ground, linear in between (IS 6403 cl. 5.1.2).
  • Settlement must be checked separately (IS 8009); the allowable bearing pressure is the lower of the net safe bearing capacity and the pressure causing permissible settlement.